Response of Masonry Infilled Rc Frame Under Horizontal Seismic force

No Thumbnail Available

Date

2005-07

Journal Title

Journal ISSN

Volume Title

Publisher

Addis Ababa University

Abstract

Equivalent strut approach coupled with modified Bouc-Wen model for hysteretic behavior has been adapted for the analysis of masonry infilled RC frame. Modification of Bouc-Wen model includes stiffness and strength degradations as well as pinching in the infill panel. Default values for some of the parameters involved in the hysteretic model are adopted from the manual of IDARC-2D version 6.0. A simplified program developed in substitute of IDARC-2D is the backbone of this paper. The program assumes the beams as rigid elements embodied in the floor slabs and the deformation of columns in linearly elastic behavior. Four frames having the same number of stories but different number of bays are analyzed using the program. Only the first bay, whose aspect ratio (L/H) subject to variation from 1.0 to 3.0, has been infilled with masonry. Comparative analysis of shear in the left end column is performed for the infilled frame and corresponding bare frame. Static analysis using fundamental period and response spectrum curve based on EBCS-8 is carried out to compare the results of analysis of the program. Key words: Infill; Macro-model; Hysteretic; Degradation; Aspect ratio.

Description

Keywords

Infill; Macro-Model; Hysteretic; Degradation; Aspect Ratio.

Citation