Experimental Investigation on Interface Shear and Tensile Strength Between Old and New Concrete at Different Moisture Condition

dc.contributor.advisorEsayas, Gebreyouhannes (PhD)
dc.contributor.authorJemal, Kedir
dc.date.accessioned2020-11-24T05:15:42Z
dc.date.accessioned2023-11-11T12:56:33Z
dc.date.available2020-11-24T05:15:42Z
dc.date.available2023-11-11T12:56:33Z
dc.date.issued2020-10
dc.description.abstractThis research work is dedicated to experimental investigation on interface shear and tensile strength between old and new concrete. Twenty Push-off specimens were cast on the experimental program of the shear test. Nine specimens were monolithically cast and eleven specimens were cast with an interface. The surface of the substrate concrete was left as cast. The shear specimen was tested by varying confinements i.e. without confinement bar, with 100 and 125 initial confining strains. In addition to the above parameters, environmental conditions i.e. dry and wet conditions were also considered in this research. It was observed from this experimental program that the presence of an interface between old and new concrete causes a reduction of shear and tensile strength. For shear specimens, a reduction in shear strength of 77.39 %, 54.07 % and 38.92% for without confinement, 100 initial confinement strain, and 125 initial confinements respectively were obtained. The presence of water also has an adverse effect on the shear strength of concrete a reduction of up to 10% was observed. Nine specimens were cast on the experimental program for the tensile test. Three specimens with interface and dog bone shaped mold were cast and tested using direct tensile test six cylindrical specimens were cast monolithically. This experimental program also indicated the presence of an interface between old and new concrete reduces tensile strength by 50%-70%. The roughness of the shear specimen was measured. For monolithically cast surface arithmetic mean deviation of the profile, Ra coefficient, was higher and for cast with interface sample, Ra was smaller. The roughness was measured for five specimens. Evidently, as mean roughness increases shear bond strength also increase. A model of the specimen for both shear and tension without an interface was simulated on a nonlinear finite element analysis program DuCOM-COM3 for monotonic loading. The ultimate load was captured in fair proximity with the model.en_US
dc.identifier.urihttp://etd.aau.edu.et/handle/12345678/23454
dc.language.isoen_USen_US
dc.publisherAddis Ababa Universityen_US
dc.subjectPush-offen_US
dc.subjectShear capacityen_US
dc.subjectDog-boneen_US
dc.subjectTensile capacityen_US
dc.subjectEnvironment conditionen_US
dc.subjectInterfaceen_US
dc.subjectBonden_US
dc.subjectConfinement strainen_US
dc.subjectMapping of surface profileen_US
dc.titleExperimental Investigation on Interface Shear and Tensile Strength Between Old and New Concrete at Different Moisture Conditionen_US
dc.typeThesisen_US

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Jemal Kedir.pdf
Size:
3.06 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Plain Text
Description: