Comparative Performance Between Xpert Mtb/Rif Assay, Led Fluorescence Microscopy, and Zn Light Microscopy for Detection of Mycobacterium Tuberculosis In Sputum Samples in Addis Ababa, Ethiopia
| dc.contributor.advisor | Taye Biniam | |
| dc.contributor.author | Dejene Daniel | |
| dc.date.accessioned | 2018-06-27T12:10:40Z | |
| dc.date.accessioned | 2023-11-06T08:57:17Z | |
| dc.date.available | 2018-06-27T12:10:40Z | |
| dc.date.available | 2023-11-06T08:57:17Z | |
| dc.date.issued | 2014-05 | |
| dc.description.abstract | Background: In Ethiopia, the main tool used to diagnosis pulmonary tuberculosis is Ziehl-Neelsen microscopy. The emergence of drug-resistant forms of tuberculosis which needs moreresources to detect, to successfully treat and effectively reduce the burden is among the topchallenges in the country. Tuberculosis case detection among vulnerable population groupsincluding children, HIV positives and other high risk groups remains low due to insensitivediagnostic tools. Due to its low sensitivity, Ziehl-Neelsen microscopy does not detect all positiveTB cases among TB suspects; as a result tuberculosis transmission by false negative casesincreases. Therefore, there is a need to assess the incremental value of new diagnostic tool likeXpert MTB/RIF assay and Light Emitted Diode Fluorescent microscopy for tuberculosisdetection in our setting. Objective of the study: To determine the performance of Xpert MTB/RIF assay in comparisonwith Light Emitted Diode Fluorescent microscopy and Ziehl-Neelsen smear microscopy fordetection of Mycobacterium Tuberculosis in sputum samples in Addis Ababa. Methods and Materials: A prospective cross-sectional study from December, 2013 to April,2014 was conducted in AAHRL to compare the performance of light emitting diode fluorescentmicroscopy (LED-FM), Xpert MTB/RIF assay and Ziehl-Neelsen(ZN) smear microscopy in thediagnosis of pulmonary tuberculosis (PTB) Adult patients. LJ culture media was used as the goldstandard for sub-samples. All data was entered into an excel spreadsheet, then transfer andanalyzed using SPSS version 20. Descriptive statistics was performed and data presented intables. McNamara’s and Kappa statistics was used for proportion and the percent agreementanalysis. Results: A total of 358 pulmonary tuberculosis and MDR-TB (Multi drug resistance tuberculosis) suspected patients were enrolled from December, 2013 to April, 2014 in AddisAbaba Health research and Laboratory with mainly young adults of median age 30.5. Afterexcluding 8 samples that were invalid by Xpert MTB/RIF assay 350 samples were analyzedstatistically and The percent agreement between Light Emitted Diode Fluorescent microscopyand Ziehl-Neelsen smear microscopy, Xpert MTB/RIF assay and Light Emitted DiodeFluorescent microscopy, Xpert MTB/RIF assay and Ziehl-Neelsen smear microscopy for MTBdetection showed that k=75%(95%CI,67% to 81%), p<.0005, k=81.8%(95%CI, 81% to 82.6%)p<.0005 and k=72.6%(95%CI,61.6%to82.6%), p<.0005, respectively. The percent agreement of the three tests showed that there were an overall percent agreement of 87.4%, 84.6%, and 90.9%between Light Emitted Diode Fluorescent microscopy and Ziehl-Neelsen microscopy, XpertMTB/RIF assay and Ziehl-Neelsen microscopy, and Light Emitted Diode Fluorescentmicroscopy and Xpert MTB/RIF assay respectively. In the sub group study the sensitivity,specificity, PPV and NPV achieved with direct Ziehl-Neelsen microscopy, Light Emitted DiodeFluorescent microscopy and Xpert MTB/RIF using culture as a gold standard in 167(47%)samples were (76.9%, 96%, 97.8% and 64%), (81.2%, 90%, 95%, 67.2%) and (89.7%, 92%,96.3%, 86.2%) respectively. Conclusion: Xpert MTB/RIF assay has better yield than Light Emitted Diode Fluorescent smearmicroscopy and Ziehl-Neelsen smear microscopy with incremental yield of 12.8% and LightEmitted Diode Fluorescent smear microscopy has better yield than Ziehl-Neelsen smearmicroscopy with incremental yield of 4.8% therefore Xpert MTB/RIF assay is a highly accurate diagnostic tool for MTB detection, which achieves a substantial reduction in diagnostic delayWith overall performance characteristics that are superior to Light Emitted Diode Fluorescentsmear microscopy and Ziehl-Neelsen smear microscopy. Keywords: Light Emitting Diode Fluorescent Microscopy (LED-FM), Ziehl-Neelsen (ZN), Xpert MTB/RIF assay | en_US |
| dc.identifier.uri | http://etd.aau.edu.et/handle/123456789/4200 | |
| dc.language.iso | en | en_US |
| dc.publisher | Addis Ababa University | en_US |
| dc.subject | Light Emitting Diode Fluorescent Microscopy (LED-FM) Ziehl-Neelsen (ZN) Xpert MTB/RIF assay | en_US |
| dc.title | Comparative Performance Between Xpert Mtb/Rif Assay, Led Fluorescence Microscopy, and Zn Light Microscopy for Detection of Mycobacterium Tuberculosis In Sputum Samples in Addis Ababa, Ethiopia | en_US |
| dc.type | Thesis | en_US |