External Quality Assessment Performance and Associated Factors in Selected Governmental Clinical Bacteriology Laboratories in Ethiopia

dc.contributor.advisorWoldie, Mistire(Dr.)
dc.contributor.advisorSisay, Abay (MSc.)
dc.contributor.authorAssefa, Dawit
dc.date.accessioned2020-01-30T13:49:02Z
dc.date.accessioned2023-11-06T08:56:27Z
dc.date.available2020-01-30T13:49:02Z
dc.date.available2023-11-06T08:56:27Z
dc.date.issued2019-10
dc.descriptionThis is to certify that the thesis prepared by Dawit Assefa Wendifraw entitled: External Quality Assessment Performance and Associated Factors in Selected governmental Clinical Bacteriology Laboratories in Ethiopia A research thesis submitted to the Department of Medical Laboratory Sciences, College of Health Science, Addis Ababa University, in partial fulfillment of Master of Science Degree in Clinical Laboratory Sciences (Laboratory management and quality assurance track) complies with the regulations of the University and meets the accepted standards with respect to originality and qualityen_US
dc.description.abstractBackground: External quality assessments (EQA) at various level of the health system are very helpful in the identification of possible nonconformance in laboratory. Moreover, it helps develop guidelines for remedial actions to be taken for the improvement of laboratory services with ultimate goal of attaining better health care and patient outcome. Objective: To assess selected government clinical bacteriology laboratories external quality assessment performance and associated factors in Ethiopia from July 2018 up to May 2019. Methods: A cross sectional study design using both a prospective and retrospective data approach was employed among 16 bacteriology laboratories from July 2018 to May 2019. From One world accuracy PT sample provider they obtained seven panel tests: bacterial identification from sputum, blood, eye swab, wound and CSF; throat swab; urine; genital; N. gonorrhoea identification; gram stain; and AST. In addition, four standard bacterial strains were prepared in house and distributed to participant laboratories. Data were collected using pre-tested structured questionnaire as well as on-site observation. The collected data was cleaned and analyzed using Stata14.2 and exact logistic regression. P <0.05 was considered as statistically significant. Results: The overall failure rate of bacterial identification during event two from CSF, blood and Abdominal abscess, was 7/13(53.8 %); from throat culture 8/13(61.5%), from urine 5/13(38.46%), and from genital cultures 8/13(61.5%) from gram staining 7/15(46.6%) and for N. gonorrhea ID the failure rate was 2/14(14.2%). On the other hand, the failure rate from event three were: from sputum, blood and eye swab 14/16 (87.5 %), from urine 7/16(43.8%), from throat 8/15(53.3%), from genital culture 9/16(56.3%), from gram staining 5/16(31.3%) and for N.gonorrhoea ID the failure rate was 7/15(46.7%). The overall AST failure rate of the laboratories during event 2 and 3 were 8/10(80%), and 8/13(62%) respectively. Fifteen laboratories were participated in house prepared PT samples for bacterial ID and AST were the failure rate from pus 1/15(6.66%),sputum 3/15(20%),blood 5/15(33.3%),AST 1/15(6.66%) .The foremost identified contributing factories for unsuccessful PT results includes mis utilization of updated SOPs, no use of McFarland standard, unable to perform internal quality control for Gram staining, culture media, identification reagents, and antibiotic discs (p<0.05). Conclusion: The overall EQA performance of participant clinical bacteriology laboratories was poor. The main associated factors were poor implementation of quality management system such as poor records and documentation, poor internal quality control practices, no regular competency assessment, VII lack of refreshment on basic microbiology training Therefore, continues training and mentorship for laboratories participating in external quality assurance are mandatory.en_US
dc.identifier.urihttp://etd.aau.edu.et/handle/123456789/20529
dc.language.isoenen_US
dc.publisherAddis Ababa Universityen_US
dc.subjectProficiency testing; Quality assessment; bacterial identification; antibiotic susceptibility testingen_US
dc.titleExternal Quality Assessment Performance and Associated Factors in Selected Governmental Clinical Bacteriology Laboratories in Ethiopiaen_US
dc.typeThesisen_US

Files

Original bundle
Now showing 1 - 2 of 2
No Thumbnail Available
Name:
Dawit Assefa External Quality Assessment Performance and Associated Factors in Selected Governmental Clinical Bacteriolog~1.pdf
Size:
926.32 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
1_Dawit Assefa External Quality Assessment Performance and Associated Factors in Selected Governmental Clinical Bacteriolog~1.pdf
Size:
926.32 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Plain Text
Description: