A Research Thesis on Perioperative Adverse Events and Outcomes of Rigid Bronchoscopy for Pediatric Foreign Body Aspiration Removal at Tikur Anbesa Specialized Hospital: A Prospective Observational Study from September 1, 2025 To January 30, 2026

dc.contributor.advisorAmria Shamil
dc.contributor.advisorAmanuel Yishak
dc.contributor.authorAssefa Bassie
dc.date.accessioned2026-11-13T13:12:57Z
dc.date.available2026-11-13T13:12:57Z
dc.date.issued2026
dc.description.abstractBackground: Foreign body Aspiration is a life-threatening emergency situation among pediatric age group worldwide. Prompt diagnosis and removal are critical; however, the procedure itself carries significant anesthetic and surgical risks. Objective: This study aims to comprehensively determine Perioperative Adverse Events and Outcomes of Rigid Bronchoscopy for pediatric Foreign Body Aspiration Removal at Tikur Anbesa Specialized Hospital: under a Prospective Observational Study in the study period. Materials and Methods Institution-based prospective observational study was done on 56 patients who had confirmed or suspected FBA with census sampling method, standardized and structured questionnaires were used. The collected data was cleared and entered to SPSS version 27. Descriptive and chi square test analysis was done. Result: Thirty-five (62.5%) had complications, hypoxia was the leading (58.9%), which has moderate improvement compared to 2020 study in TASH (85%) but still the incidence of hypoxia is higher compared to other developed countries. The independent predictors of intraoperative complication were number of broncoscopic retrievals more than 3 (AOR: 9.52, 95%CI: 2.65-34.2, P= 0.001) followed by preoperative oxygen requirement (AOR: 6.18, 95% CI: 1.48 – 25.90, p=0.011 and preoperative pulmonary infection (AOR: 5.12 95% CI: 1.15-22.85, P=0.032). Eight patients were admitted to ICU intubated. The independent predictor of ICU admission were the occurrence of post op complications (AOR: 11.45, 95% CI: 2.51-52.4, P=0.002), followed by preoperative pulmonary infection (AOR: 6.12, 95% CI (1.35 – 27.80), P=0.018. Conclusion: Bronchoscopic foreign body aspiration removal remains high risk procedure which is associated with frequent intraoperative adverse events. Success rate of FBAR was good and no deaths recorded despite higher intraoperative adverse events. The commonest intraoperative complication was hypoxia. Number of broncoscopic attempts more than 3 times followed by preoperative oxygen requirement and preoperative pulmonary infections were the strongest independent predictors of the occurrence of intraoperative adverse events. The ICU admission rate was higher. The independent predictors of ICU admission were the occurrence of post op complications followed by preoperative pulmonary infection.
dc.identifier.urihttps://etd.aau.edu.et/handle/123456789/9608
dc.language.isoen
dc.publisherAddis Ababa University
dc.subjectForeign body Aspiration
dc.subjectFBA Removal
dc.subjectBronchoscopy
dc.subjecthypoxia
dc.subjectadverse event
dc.subjectoutcome
dc.titleA Research Thesis on Perioperative Adverse Events and Outcomes of Rigid Bronchoscopy for Pediatric Foreign Body Aspiration Removal at Tikur Anbesa Specialized Hospital: A Prospective Observational Study from September 1, 2025 To January 30, 2026
dc.typeThesis

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Assefa_ Bassie_2026_ETD.pdf
Size:
613.97 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: