Evaluation of Same Day Diagnosis of TB Microscopy in Comparison to the Spotmorning-spot Method and Knowledge, Attitude and Practice of Health Personnel towards the Use of the Same Day Diagnosis of TB in Selected Health Institution in Addis Ababa, Ethiopia.

dc.contributor.advisorDesta Kassu
dc.contributor.advisorAli Ibrahim
dc.contributor.advisorAgonafir Mulualem
dc.contributor.authorkebede Sisay
dc.date.accessioned2021-06-18T08:00:32Z
dc.date.accessioned2023-11-06T08:56:49Z
dc.date.available2021-06-18T08:00:32Z
dc.date.available2023-11-06T08:56:49Z
dc.date.issued2012-06
dc.description.abstractBack ground: the need to collect serial sputum specimens over multiple patient visits results in aprotected diagnostic process with rates of patients with high rates of patient dropout. Recentstudies on SMS method of examination PTB reported that the first two specimens have highsmear positivity in line with this WHO changed its policy to minimize the number of sputumspecimens from three to two. Objective: The main objective of this study was to evaluate the same day diagnosis of TBmicroscopy in comparison to the spot-morning-spot methods and KAT of lab personnel, GP, HOand Nurse to wards the use of the same day diagnosis of TB in selected health institutions inAddis Ababa. Material and method: Across sectional study were conducted in 16conveniently selectedprivate clinics, governmental health centers, public hospitals and private hospitals, federal policeand armed force hospital from September – December 2012.All patients who were availthemselves in the selected health institutions for the diagnosis of MTB and those health personalwho were worked in each health facility. The diagnosis was performed using ZN sputum smearmicroscopy and light-emitting diodes fluorescent microscopy (LED-FM) technique. A structureand pre-validate questionnaires was used to collect data for KAP survey. Chi-square was used toassess the associations’ different variables of techniques and health personals KAP study. Result: A total of 209 participant enrolled, 43(21%) were identified culture positive,39 (18.7%)were detected by the same day approach and 40(19.1%) by the standard approach (p>0.05).onthe other hand LED-FM and ZN microscopy were identified 39(18.1%) and 48(23%)respectively. Sensitivity was (88.4%) for ZN microscopy and (95.3%) for LED-FM, it was(99.4%) and (95.9%) for specificity. More over the mean and median knowledge, practice and attitude score of laboratory personalabout the same day diagnosis was 4.07, 5.96, 7.67 and 5, 5, 8 respectively. Majority(61%),(73%) and (97%) of Laboratory personal had good knowledge, practice and positiveattitude while the mean and median knowledge score was 4.7 and 4 respectively, but the meanand median attitude and practice was 6.65, 6.4 and 8.7 respectively .majority (57.7%),(63.4%)and (72.4%) of other health personal had poor knowledge, positive attitude and good practicerespectively. using same day approach together with LED-FM would increase the smear detection rate,reduce work load, TAT, patient and health facility cost and transmission of TB. Hence, it isessential to address the advantages and dis advantages of the conventional approaches, LED-FMand same day diagnosis of TB to raise KAPs` of health personnel. Therefore it is necessary to give in-service and off service training for health personnel towardsthe use of LED-FM, conventional approach and the same day approach in the diagnosis of TB en_US
dc.identifier.urihttp://etd.aau.edu.et/handle/123456789/26913
dc.language.isoen_USen_US
dc.publisherAddis Abeba Universityen_US
dc.subjectTB,TB microscopyen_US
dc.titleEvaluation of Same Day Diagnosis of TB Microscopy in Comparison to the Spotmorning-spot Method and Knowledge, Attitude and Practice of Health Personnel towards the Use of the Same Day Diagnosis of TB in Selected Health Institution in Addis Ababa, Ethiopia.en_US
dc.typeThesisen_US

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Sisay_kebede_2012_ETD.pdf
Size:
855.49 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Plain Text
Description: