Evaluation of Genexpert Mtb/Rif Assay for Diagnosis of Pulmonary Tuberculosis and Detection of Rifampicin Resistance in Sputum Specimens At Kharamara Hospital, Jigjiga, Eastern Ethiopia

dc.contributor.advisorDesta Kassu
dc.contributor.authorAssefa Dereje
dc.date.accessioned2018-06-27T13:35:56Z
dc.date.accessioned2023-11-06T08:56:54Z
dc.date.available2018-06-27T13:35:56Z
dc.date.available2023-11-06T08:56:54Z
dc.date.issued2014-06
dc.description.abstractBackground: TB detection rate remains critical stumbling block for TB control. Thoughconventional methods for TB detection exist; GeneXpert MTB/RIF assay represents a paradigmshift in the diagnosis of TB and MDR-TB by simultaneous detection of M.tuberculosis andrifampicin resistance bacilli. However information regarding the performance characteristics ofXpert MTB/RIF assay is scarce in Ethiopia. Objective: To evaluate the performance of Xpert MTB/RIF assay for diagnosis of pulmonarytuberculosis and detection of Rifampicin resistance in sputum specimens at Karamara hospital,Jigjiga. Materials and methods: A total of 227 paired expectorated sputum samples from patients withsigns and symptoms of suggestive of tuberculosis at Karamara hospital during February 2014 toMay 2014 were recruited by consecutive sampling method. Sputum sample was tested directlyby Ziehl-Neelsen staining and Xpert MTB/RIF assay without NALC-NaOH decontaminationand sputum samples were cultured for isolation and drug sensitivity testing of TB bacilli.Diagnostic performance of Xpert MTB/RIF assay and AFB smear microscopy was calculatedusing sensitivity, specificity, positive and negative predictive values, positive and negativelikelihood ratios against culture as the gold standard. Results with contaminated cultures (forboth LJ and MGIT) and failed Xpert MTB/RIF were excluded from analysis. Results: Overall 25.5% (58/227) samples were positive for MTBC by MGIT and/or LJ media ofwhich 36.2 % (21/58) and 65.5% (35/58) were positive by AFB smear microscopy and XpertMTB/RIF respectively. The sensitivity, specificity, positive and negative predictive value ofXpert MTB/RIF assay were 65.5% (95% CI: 53.3-77.7%), 96.3% (95% CI: 93.4-99.2%), 86.4%(95% CI: 76.2-96.5%), and 88.6% (95% CI: 83.9-93.3%) respectively. Eighteen (31.0%, 18/58)more cases, which were smear microscopy negative, were detected by Xpert MTB/RIF assay Conclusion: Xpert MTB/RIF assay demonstrated high sensitivity in detecting MTBC in sputumspecimens compared with conventional AFB smear microscopy. However, it demonstratedsuboptimal sensitivity in smear negative patients compared to culture test. Keywords: Xpert MTB/RIF assay, NPV, PPV, Sensitivity, Specificity en_US
dc.identifier.urihttp://etd.aau.edu.et/handle/123456789/4261
dc.language.isoenen_US
dc.publisherAddis Ababa Universityen_US
dc.subjectXpert MTB/RIF assay NPV, PPV Sensitivity, Specificityen_US
dc.titleEvaluation of Genexpert Mtb/Rif Assay for Diagnosis of Pulmonary Tuberculosis and Detection of Rifampicin Resistance in Sputum Specimens At Kharamara Hospital, Jigjiga, Eastern Ethiopiaen_US
dc.typeThesisen_US

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Dereje_Assefa_2014_ETD.pdf
Size:
411.39 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Plain Text
Description: