Repository logo
  • English
  • CatalĆ 
  • ČeÅ”tina
  • Deutsch
  • EspaƱol
  • FranƧais
  • GĆ idhlig
  • Italiano
  • LatvieÅ”u
  • Magyar
  • Nederlands
  • Polski
  • PortuguĆŖs
  • PortuguĆŖs do Brasil
  • Srpski (lat)
  • Suomi
  • Svenska
  • TürkƧe
  • Tiįŗæng Việt
  • ŅšŠ°Š·Š°Ņ›
  • বাংলা
  • ą¤¹ą¤æą¤‚ą¤¦ą„€
  • Ελληνικά
  • Дрпски
  • YŠŗŃ€Š°Ń—ĢŠ½ŃŃŒŠŗŠ°
  • Log In
    New user? Click here to register. Have you forgotten your password?
Repository logo
  • Colleges, Institutes & Collections
  • Browse AAU-ETD
  • English
  • CatalĆ 
  • ČeÅ”tina
  • Deutsch
  • EspaƱol
  • FranƧais
  • GĆ idhlig
  • Italiano
  • LatvieÅ”u
  • Magyar
  • Nederlands
  • Polski
  • PortuguĆŖs
  • PortuguĆŖs do Brasil
  • Srpski (lat)
  • Suomi
  • Svenska
  • TürkƧe
  • Tiįŗæng Việt
  • ŅšŠ°Š·Š°Ņ›
  • বাংলা
  • ą¤¹ą¤æą¤‚ą¤¦ą„€
  • Ελληνικά
  • Дрпски
  • YŠŗŃ€Š°Ń—ĢŠ½ŃŃŒŠŗŠ°
  • Log In
    New user? Click here to register. Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Molla Habtamu"

Now showing 1 - 6 of 6
Results Per Page
Sort Options
  • No Thumbnail Available
    Item
    Assessment of Factors Affecting Quality of Clinical Laboratory Service in Health Facilities at South West Shewa Zone, Oromia, Ethiopia.
    (Addis Abeba University, 2021-01) Wakuma Tamirat; Hassen Fatuma; Molla Habtamu; Tsegaye Aster
    Background: A quality medical laboratory service is an important part of the health care system.Commitment of the health personnel, administration and policy makers contribute to thecontinuous improvement of diagnosis. In developing countries like Ethiopia, the laboratoryquality system remains weak due to several factors. Therefore, assessing the factors affectingquality of medical laboratory service is highly important in order to improve service quality. Objective: To assess factors affecting the quality of medical laboratory service in South WestShewa Zone Health Facilities, Oromia, Ethiopia, January 2020 to May 2020. Methods: An institution based cross-sectional study was conducted at South West Shewa ZoneHealth Facilities from January 2020 to May 2020. A pretested, structured questionnaire andchecklist was used to collect the socio-demographic information of the study participants and toassess factors affecting the provision of quality medical laboratory services. Data were checkedfor completeness, entered, and analyzed using SPSS version 24. The strength of associationbetween the dependent and independent variables was assessed using binary and multiple logisticregression analysis. A p-value < 0.05 was considered statistically significant. Results: A total of 85 medical laboratory professionals participated in the study. Of these, 68(80%) were males and 27 (31.8%), were laboratory technologists. Of them 78 (91.8%) were notsatisfied with their salary. Thirty-two (37.6%) of the participants reported that their laboratorydid not provide quality laboratory service. Lack of Quality Manual, Lack of staff recognition andnot conducting Internal Quality control activitieswere the major factors significantly associatedwith poor quality laboratory service (p < 0.05).High work load was identified as the highesttechnical factor influenced the provision of quality laboratory services 56.1%, followed byEquipment Failure 20% and from administrative factors shortage of resources was rated highest39% followed by poor staff commitment 23.4%. Conclusions:More thanOne third of the study participants reported that their laboratory did notprovide quality laboratory services. Lack of quality manual, not conducting internal qualitycontrol activities and Lack of staff recognitionare the major factors associated with poor qualityof laboratory services. Hence timely intervention of these factors is warranted since a third of theparticipants believe their laboratory does not provide quality service.
  • No Thumbnail Available
    Item
    Assessment of Gram Stain Competency and Associated Factors among Laboratory Professional in Clinical Laboratories at Mekelle City Health Facility, Mekelle, Ethiopia
    (Addis Abeba University, 2020-05) Miruts Fikadu; Hassen Fatuma; Molla Habtamu
    Background: Cytopenias are one of the most common complications in HIV and TB/HIV coinfectedpatients. Assessing immuno-hematological outcome is very essential for the managementand care of people living with HIV and TB/HIV co-infection. Objective: To determine the Immuno-Hematological changes among HIV and TB/HIV co-infectedpatients taking HAART for at least six months at Menelik II Referral Hospital. Methods: This cross-sectional study was conducted on 338 HIV infectedpatients who have beentaking HAART for at least six months. Socio-demographic, clinical, CD4+ T cells andhematological data at baseline and after at least 6 months on HAART were extracted from Februaryto March 2019. Student t-test was used to compute the difference between baseline and currenthematological and CD4+ T cells values. SPSS version 20 was used for data entry and analysis.P<0.05 was considered as statistically significant. Results: Of the total 338 individuals, 255 (75.4%) were infected with HIV only and 83 (24.6%)were TB/HIV co-infected. There was significant increase (p<0.05) in the mean CD4 (164.6 vs 317.1 cells/l), WBC (5.89 vs 6.49Ɨ103/l), Hgb (13.07 vs 13.76g/dl), platelets (245 vs 265Ɨ10/l),MCV (89.92 vs 96.13fl), MCH (30.25 vs 32.69pg) and a decrease in RBC (4.35 vs 4.25Ɨ10/l)after six months of HAART. Compared to baseline, there was also significant decrease in the rate of Immunosuppression (CD4<350; 98.5 vs 88.5), anemia (39.9 vs 14.5%), leucopenia (22.2 vs 17.8%),neutropenia (11.5 vs 9.2%) and thrombocytopenia (16.9 vs 9.8%) after 6 months of HAART. Whendata was analyzed for HIV/TB co-infected patients separately, the effect of TB co-infection onHAART outcome was evident. The respective baseline and current values in this group were: CD4,149.58 vs 294.72, WBC 5.83 vs 6.62, Hgb 12.25 vs 12.91, PLT 264.1 vs 262.9, RBC 4.22 vs 4.14,MCV 89.5 vs 92.6, MCH 29.54 vs 31.17 (P<0.05 for WBC, PLT, CD4, MCV). Rates ofImmunosuppression was 98.8 vs 92.8%, anemia 51.8 vs 39.8%, leucopenia 21.7 vs 18.1%,neutropenia 10.8 vs 12.1%, thrombocytopenia 14.5 vs 12.0%. Besides, patients taking AZT baseddrugs had significantly higher MCV and MCH values (P<0.01) than those who did not. Conclusion: It is evident from this study that has shown significant improvements in immunohematological profiles aftertakingHAART for at least 6 months. The changes were more affectedwith TB co-infection suggesting further investigation considering HAART adherence. 36
  • No Thumbnail Available
    Item
    Assessment of knowledge, Attitude , Practice (KAP) and Associated Factor of Clinical Laboratory Proffessionals in Use of IQC for Laboratory Tests among Selected Public and Private Hospitals in Addis Ababa
    (Addis Abeba University, 2020-06) Ayele Marta; Hassen Fatuma ; Molla Habtamu
    Background: A well-organized Laboratory Quality Assurance Program includes InternalQuality Control (IQC) procedures, External Quality Assessment (EQA) programs andLaboratory Quality Management (LQM). IQC is a set of procedures that are used in daily routinework to control daily variance of test results, problems are identified immediately and themethod is brought back on track. So it needs professionalsā€˜ knowledge and commitment. Internalquality control (IQC) in laboratory is a crucial part of quality processes.so that poor practices ofprofessional on IQC affect the result of patients. That is why this study raises the question ofKAP of laboratory professionals in use of IQC among selected public and private hospitals inAddis Ababa. Objective: To assess knowledge, Attitude and Practice of clinical laboratory proffessionals andassociated factors in use of IQC for laboratory tests among selected public and private Hospitalin Addis Ababa, Ethiopia. Methods: A cross sectional study was conducted using questionnaire to assess KAP oflaboratory professionals and its associated factors in use of IQC among selected public andprivate hospitals in Addis Ababa from February 2020 to April 2020.A total of 250 laboratoryprofessionals from selected public and private Hospitals were participated in the study. Pre-testedand self-administered questionnaire were used .Data entry and analysis were performed by usingSPSS version 20 software. Descriptive statistics, such as mean, median, analysis were used.Association of different factors with KAP of laboratory professionals were done using the Binarylogistic regression and level of statistical significance was set at p<0.05 Results: From the total of two hundred fifty participants, (response rate, 100%) 147 (58.8%)were male. In this study 220(88.0%), 224(89.6%) and 168(67.2%) study participants had goodknowledge, positive attitude and good practice towards IQC, respectively. The mean number ofB test menu was 29.16 (SD +2.38), minimum 21 and maximum 33.from their available number oftests no one practice IQC for more than 80% of the tests, around half (52.8%) of the personnelpractice IQC for only 50-65% of the available tests. Conclusion: Even though majority of participants had good knowledge and attitude towardsIQC, around one third of them had poor practice on IQC in the laboratory, there reasons formajority participant were shortage of QC material. There was no significant difference on KAPof laboratory professionals from public and private hospitals towards IQC. No risk factors wereobserved for poor knowledge and negative attitude towards IQC. Practice for all test hadsignificant association with LQM training, duration of training and having schedule for IQC.
  • No Thumbnail Available
    Item
    Assessment of Specimen Rejection Rate and Associated Factors among Samples Referred to Addis Ababa Research and Emergency Management Core Process Laboratory, Addis Ababa, Ethiopia
    (Addis Abeba University, 2021-02) Adugna Berisa; Tsegaye Aster ; Molla Habtamu
    Background: Accurate laboratory results are vital for patient safety and improving the medicaldiagnosis. Most errors occurred in the pre-analytic phase. Improper collection of samples canlead to sample rejection. In this case laboratory should establish rejection criteria and followthem closely. Specimen rejection may have significant consequences for patients and theirclinical management. Thus, understanding the magnitude and taking appropriate action is criticalfor quality laboratory service provision. Objective: to assess the Specimen rejection rates and associated factors among samples referredto the laboratory of Addis Ababa Research and Emergency Management core process. Methods: cross sectional study was conducted using both primary and secondary data whichassesses the rate and reason of rejection observed from June 01, 2018 to May 30, 2020 G.C.About 131,909 specimens collected at Addis Ababa Research and Emergency management coreprocess laboratory with in the period of the study was entered and analyzed using SPSS 20. Result: a total of 131,909 specimens were sent to central reception of the Addis Ababa publichealth research and Emergence management core processes laboratory. The total rejection ratewas 0.69%, 915. The frequencies of rejected specimens were highest in viral load 35.1%,followed by clinical chemistry which was 23.4%. The most common reason of rejection wasmislabeling, 27.1%, followed by insufficient 15.8%, and clotted 15.1% specimen. Amongrejected specimens, 514 specimens were rejected in the first and 401 Specimens were rejected inthe second. Conclusions: The study demonstrated about 0.7% specimen rejection rate. Alongside of theefforts to minimize laboratory error, this study highlighted a complexity of pre-analytical errorsto minimize them. The most commonly rejected specimens were for viral load followed byclinical chemistry samples. The most common pre analytical reason for specimens’ rejection wasmislabeling, followed by insufficient and clotted specimens.
  • No Thumbnail Available
    Item
    Frequency of Specimen Rejection and Associated Factors at St. Paul Hospital Millennium Medical College, Addis Ababa, Ethiopia
    (Addis Ababa University, 2014-04) Molla Habtamu; Tsegaye Aster
    Introduction: Laboratory testing is an integral part of the clinical decision-making process,and results of laboratory testing often strongly influence medical diagnoses and therapies.Quality of specimen is an important factor that affects the accuracy and usefulness oflaboratory results. The problem is high in resource poor countries like our country, EthiopIdentifying the types, frequency and associated factors influencing the quality of clinicalsamples is important for designing appropriate interventions to prevent their generationand Serology departments. Compared with the respective frequency with which they collectthe specimen, laboratory personnel had significantly fewer rejected specimens thanNonlaboratory personnel. The proportion of specimens that were rejected in emergencydepartment and inpatient services were twice more than for the outpatient services. Conclusion: Our finding shows the problems of specimens in the preanalytic phase and thefactors involved in rejection of specimens, particularly with respect to specimen collectionsperformed outside the laboratory walls by Nonlaboratory personnel who are not under thedirect control of the laboratory; moreover, the finding shows that the rates of specimenrejection are higher for inpatients and ED than outpatients, owing to the performance ofoutpatient procedures by personnel under direct laboratory control.and hence improving the quality of laboratory service. Different literatures showed thatmore than 70% of errors in the laboratory occur in the pre analytical phase. Objective: The purpose of the study is to determine the frequency of specimen rejectionand associated factors of specimens submitted for different tests to the St. Paul hospitalmillennium medical college, Addis Ababa, Ethiopia. Methods: Cross sectional study design was applied at St. Paul hospital millennium medicalcollege medical laboratory. A total of 8063 specimens were collected during the studyperiod. The quality of all specimens submitted to laboratory during data collection periodwere checked and inappropriate specimens were recorded in data collection checklistformat. The data was entered and analyzed using SPSS version 16.0 software. Result: Of 8063 total specimens submitted for testing to the laboratory of St. Paul hospitalmillennium medical college during the data collection period, 116(1.4%) were rejected. Themost frequent reason for rejection was hemolysis of specimen, which occurred much morefrequently than the second most cited reasons, clotted specimens and unlabelledspecimens. Compared with their respective frequency of rejection of specimens by type ofrequested laboratory service, significantly more rejected specimens occurred in Hematolog
  • No Thumbnail Available
    Item
    Specimen Rejection Rate and Associated Factors among Referred Specimens Through Referral Network to Debre Markos Referral Hospital for Laboratory Testing, Debre Markos, Ethiopia
    (Addis Abeba University, 2020-06) Mesganaw Bewket; Hassen Fatuma; Molla Habtamu
    Background: Clinical laboratory errors could be classified as pre analytical, analytical and postanalytical. The majority of laboratory errors emerge from the manually intensive activities of thepre analytical phase, mainly those related to collection, handling, transportation, preparation andstorage of diagnostic specimens. Objective: The main aim of this study was to assess the specimen rejection rate and associatedfactors among the referred specimens through referral network to Debre Markos referral hospitalfor laboratory testing. Method: Retrospective study was conducted at Debre Markos referral hospital laboratory fromJanuary 2016 to December 2019 to evaluate trends of specimen rejection rate. In addition,prospective cross sectional study design was applied from January 2020 to April 2020 toinvestigate further associated factors of specimen rejection. Data was collected from specimenreception log book and from referring facilities using developed checklist. Finally, statisticalanalysis was done with excel 2007 and SPSS version 20.0 software. Result: From the total of 35673 specimens submitted to Debre Markos referral hospitallaboratory from January 2016 to December 2019, a total of 560 (1.57%) specimens wererejected. The specimen rejection rates in each year were 2.30%, 1.59%, 1.42% and 1.26 %respectively from 2016 to 2019. Moreover, of 2750 specimens submitted to the laboratory duringJanuary 2020 to April 2020, a total of 37 (1.34%) specimens were rejected. Specimen collectortraining status and experience had significant association with specimen rejection rate (P= 0.01& P=0.04 respectively). Conclusion: Although specimen rejection rate among referred specimens was improvedgradually from 2016 to 2019, still needs more interventions to meet the established targetspecimen rejection rate (0.3%).Hence, training of health professionals on specimen collection,handling and transportation of requested tests, appropriate preventive and corrective actionscould improve the problem in specimen referral network.

Home |Privacy policy |End User Agreement |Send Feedback |Library Website

Addis Ababa University Ā© 2023