Voltammetric Determination of Caffeine in Coffee Using Anthraquinone Modified Carbon Paste Electrode
dc.contributor.advisor | Tessema, Merid (PhD) | |
dc.contributor.author | Seid, Kerem | |
dc.date.accessioned | 2018-06-20T08:27:56Z | |
dc.date.accessioned | 2023-11-09T16:17:39Z | |
dc.date.available | 2018-06-20T08:27:56Z | |
dc.date.available | 2023-11-09T16:17:39Z | |
dc.date.issued | 2008-07 | |
dc.description.abstract | Anthraquinone modified carbon paste electrode is used for the determination of caffeine in coffee. The optimized pH=12 value gives an advantages of undergoing square wave voltammetry of real sample with less sample pretreatment steps. A linear calibration curve is obtained over 0- 500 M in 0.1 M NaH2PO4 and Na2HPO4 buffer solution with a detection limit (3) of 5 nM. Determination of caffeine in coffee was done by subtracting the background current. (Key words: CMCPEs, anthraquinone) | en_US |
dc.identifier.uri | http://etd.aau.edu.et/handle/12345678/2159 | |
dc.language.iso | en | en_US |
dc.publisher | Addis Ababa Universty | en_US |
dc.subject | CMCPEs; anthraquinone | en_US |
dc.title | Voltammetric Determination of Caffeine in Coffee Using Anthraquinone Modified Carbon Paste Electrode | en_US |
dc.type | Thesis | en_US |