Repository logo
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Српски
  • Yкраї́нська
  • Log In
    New user? Click here to register. Have you forgotten your password?
Repository logo
  • Colleges, Institutes & Collections
  • Browse AAU-ETD
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Српски
  • Yкраї́нська
  • Log In
    New user? Click here to register. Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Tesema Desalegn"

Now showing 1 - 1 of 1
Results Per Page
Sort Options
  • No Thumbnail Available
    Item
    Stability of Complete Blood Count and 3-part White Cell Differential Parameters with Storage Time and Temperature Variation using Cell DYN 1800 Automated Hematology Analyzer
    (Addis Abeba University, 2011-07) Tesema Desalegn; Tsegaye Aster
    Background: Complete blood count (CBC) and differential white cell counts are the mostcommonly ordered tests in clinical practice. The standard operation procedures in the ARTlaboratories, which are prepared based on the instrument instruction manual of the company,recommend 8 hours storage at room temperature. However, there is no clear information as tohow to handle delayed specimens in situations where delayance is unavoidable. Objective: To evaluate whole blood stability with time, storage temperature andtransportation conditions using Cell-Dyn 1800, a 3-part diff hematological analyzer. Methods: A total of 45 adult participants, 19 from ART clinic of Tikur Anbessa SpecializedHospital and 26 apparently healthy Medical Laboratory Science students of Addis AbabaUniversity were included in the study usingconvenient sampling methods. EDTA wholeblood samples were analyzed at baseline before and after aliquoting. Each of six aliquots, forroom temperature and 2-8OC storage, one each for transporting with and without an ice boxwere used. After the baseline analysis of the direct EDTA tube and an aliquot, all specimenswere analyzed at 8, 24, 32, 56 and 72 hours of storage. Same EDTA tube was used each timeafter refrigeration. Transported samples were analyzed within 8 hours and compared withbaseline values. Cell-Dyn 1800 automated hematology analyzer was used following themanufacturers instruction. Results: Among the CBC parameters, WBC, RBC, Hgb, MCH were stable for 72 hours postsample collection regardless of storage temperature. These values were also unaffected duringtransportation. MCHC was relatively less stable. PLT counts remained stable in the direct EDTAtube samples stored at 2-8OC for 72 hours while aliquoted samples were less stable, showing adeclining trend with time. The MCV and RDW, parameters affected by change in the red cellsize showed an increasing trend with time where differences were statistically significant(P<0.05) after 48 hours of storage. WBC Differential data was the least stable of all, even after 8hours of storage, where granulocytes showed a declining trend Conclusion: The various CBC parameters showed different levels of stability at differentspecimen storage and handling conditions. Each parameter should be treated case by case inconditions where delayance is unavoidable.

Home |Privacy policy |End User Agreement |Send Feedback |Library Website

Addis Ababa University © 2023