Repository logo
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Српски
  • Yкраї́нська
  • Log In
    New user? Click here to register. Have you forgotten your password?
Repository logo
  • Colleges, Institutes & Collections
  • Browse AAU-ETD
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Српски
  • Yкраї́нська
  • Log In
    New user? Click here to register. Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Taye Biniam"

Now showing 1 - 4 of 4
Results Per Page
Sort Options
  • No Thumbnail Available
    Item
    Assessment of Focused Antenatal Care Laboratory Services Statususing Availability, Functional Status and Clients Satisfaction at Public Health Facilities Addis Ababa, Ethiopia
    (Addis Ababa University, 2015-06) Melese Daniel; Taye Biniam
    Back ground: Laboratory service is a key component of Focused Antenatal Care (FANC) to identify lifethreatening conditions of maternal and child health. Limited capacity of health facilities to provideadequate laboratory services remains a major problem for the quality of FANC service delivery. Objective: To assess the status of focused antenatal carelaboratory services using availability,functional status and client satisfaction at public health facilities in Addis Ababa, Ethiopia. Methods: Institution based, descriptive cross-sectional study was conducted from April to May 2015.Both quantitative and qualitative designs were used. Four hundred and twenty two study participantsinterviewed on satisfaction towards FANC laboratory services by using structured questionnaire. Aqualitative data was collected by In-depth interview of providers. To assess availability and functionalityof the FANC laboratory, observation check list was used. Data were coded and analysed by using SPSSVersion 20 software. Logistic regression model was also used to examine the effect of selected variableson clients’ satisfaction with laboratory services. P-Value less than 0.05 were taken as statistically significant. Result: Only 5(38.5%) out of 13 visited health facilities reported the availability of all types of basicFANC laboratory investigations. Comparing the availability of individual tests in the study facilities,urine dipstick, urine miscopy and stool examination were available in all institutions. However, only 7(53.8%) of the facilities reported the availability of Hepatitis B virus screening test. Rapid syphilis/RPRtest was found in 10 (76.9%) facilities. All laboratory facilities had at least one or more basic FANClaboratory tests interruption more than a day within the last one year due to shortage of reagent and electric power disruption. Additional analysis of pregnant women's satisfaction toward FANC laboratoryservice showed, only 56.9 % (240/422) of pregnant mothers were satisfied with FANC laboratoryservices. Those clients who waited less than one hour to get laboratory results were six times more likelyto be satisfied than those who waited more than one hours [AOR = 6.03; CI (2.86-12.67)]. Conclusion: Majority of the health facilities reported incomplete FANC laboratory investigations.Hepatitis B screening test was the lowest available test in the study facilities. Furthermore a slightlyhigher maternal dissatisfaction toward FANC laboratory service was observed compared with other institutional based study in similar settings
  • No Thumbnail Available
    Item
    Assessment of the Magnitude and Associated Factors of Turnover Intention among Nurses Working in Emergency Departments of three Selected Governmental Hospitals in Addis Ababa, Ethiopa, 2018.
    (Addis Abeba University, 2018-06) Taye Biniam; Girma Biruk; Wubetie Adualem
    Back ground: Nurses’ turnover is defined as resignation of a licensed nurse from a hospital due to various factors. However Nurses’ turnover from Emergency department can be nurses’preference of working in other departments within the same hospital or totally to leave the hospital. Actual turnover is expected to increase as the intention increases. Emergency Department nurses are especially vulnerable to turnover because of their increased potential for developing burnout and compassion fatigue in which work environment has a great role. Objective: To assess the magnitude and associated factors of turnover intention among nurses working in emergency departments of selected governmental hospitals in Addis Ababa, Ethiopia. Methods: Institution based cross-sectional study was carried out on 102 nurses conveniently in three selected governmental hospitals, Addis Ababa from February 19 to march 31 2018, using structured pre tested self-administered questionnaire. Logistic regression model was fitted and adjusted odds ratio with 95% confidence interval was calculated to identify associated factors. Result: A total of 102 respondents were involved with a response rate of 91.1%. Among them,46(45.1%) respondents had intention to leave the hospital. three significant predictors of nurses working in emergency departments ’ intention to leave their jobs: holding diploma rather than master (adjusted Odds ratio (OR) =4.700, 95% confidence interval (CI)=1.033, 590.772;p<0.048), having Less than 3145 ETB monthly income more highly (adjusted OR=6.049, 95%CI=1.056,34.641; p<0.043) and professional autonomy (adjusted OR=0.191, 95% CI=0.040, 0.908; p<0.037). Conclusion and recommendation: Nearly half of the respondents had been intention to leave the organization. Educational status; monthly income and autonomy were significantly associated with nurses‟ turnover intention in three governmental hospitals. Ward managers,ENA and MOH might have made efforts to enhance nurses‟ independent decision making for patient care activities and shared decision over work or unit related activities.
  • No Thumbnail Available
    Item
    Assessment of the Magnitude and Associated Factors of Turnover Intention among Nurses Working in Emergency Departments of three Selected Governmental Hospitals in Addis Ababa, Ethiopia, 2018
    (Addis Ababa Universty, 2018-06) Taye Biniam; Girma Biruk
    Back ground: Nurses’ turnover is defined as resignation of a licensed nurse from a hospital due to various factors. However Nurses’ turnover from Emergency department can be nurses’ preference of working in other departments within the same hospital or totally to leave the hospital. Actual turnover is expected to increase as the intention increases. Emergency Department nurses are especially vulnerable to turnover because of their increased potential for developing burnout and compassion fatigue in which work environment has a great role. Objective: To assess the magnitude and associated factors of turnover intention among nurses working in emergency departments of selected governmental hospitals in Addis Ababa, Ethiopia. Methods: Institution based cross-sectional study was carried out on 102 nurses conveniently in three selected governmental hospitals, Addis Ababa from February 19 to march 31 2018, using structured pre tested self-administered questionnaire. Logistic regression model was fitted and adjusted odds ratio with 95% confidence interval was calculated to identify associated factors. Result: A total of 102 respondents were involved with a response rate of 91.1%. Among them,46(45.1%) respondents had intention to leave the hospital. three significant predictors of nurses working in emergency departments ’ intention to leave their jobs: holding diploma rather than master (adjusted Odds ratio (OR) =4.700, 95% confidence interval (CI)=1.033, 590.772;p<0.048), having Less than 3145 ETB monthly income more highly (adjusted OR=6.049, 95%CI=1.056,34.641; p<0.043) and professional autonomy (adjusted OR=0.191, 95% CI=0.040,0.908; p<0.037). Conclusion and recommendation: Nearly half of the respondents had been intention to leavethe organization. Educational status; monthly income and autonomy were significantly associated with nurses‟ turnover intention in three governmental hospitals. Ward managers,ENA and MOH might have made efforts to enhance nurses‟ independent decision making for patient care activities and shared decision over work or unit related activities.
  • No Thumbnail Available
    Item
    Comparative Performance Between Xpert Mtb/Rif Assay, Led Fluorescence Microscopy, and Zn Light Microscopy for Detection of Mycobacterium Tuberculosis In Sputum Samples in Addis Ababa, Ethiopia
    (Addis Ababa University, 2014-05) Dejene Daniel; Taye Biniam
    Background: In Ethiopia, the main tool used to diagnosis pulmonary tuberculosis is Ziehl-Neelsen microscopy. The emergence of drug-resistant forms of tuberculosis which needs moreresources to detect, to successfully treat and effectively reduce the burden is among the topchallenges in the country. Tuberculosis case detection among vulnerable population groupsincluding children, HIV positives and other high risk groups remains low due to insensitivediagnostic tools. Due to its low sensitivity, Ziehl-Neelsen microscopy does not detect all positiveTB cases among TB suspects; as a result tuberculosis transmission by false negative casesincreases. Therefore, there is a need to assess the incremental value of new diagnostic tool likeXpert MTB/RIF assay and Light Emitted Diode Fluorescent microscopy for tuberculosisdetection in our setting. Objective of the study: To determine the performance of Xpert MTB/RIF assay in comparisonwith Light Emitted Diode Fluorescent microscopy and Ziehl-Neelsen smear microscopy fordetection of Mycobacterium Tuberculosis in sputum samples in Addis Ababa. Methods and Materials: A prospective cross-sectional study from December, 2013 to April,2014 was conducted in AAHRL to compare the performance of light emitting diode fluorescentmicroscopy (LED-FM), Xpert MTB/RIF assay and Ziehl-Neelsen(ZN) smear microscopy in thediagnosis of pulmonary tuberculosis (PTB) Adult patients. LJ culture media was used as the goldstandard for sub-samples. All data was entered into an excel spreadsheet, then transfer andanalyzed using SPSS version 20. Descriptive statistics was performed and data presented intables. McNamara’s and Kappa statistics was used for proportion and the percent agreementanalysis. Results: A total of 358 pulmonary tuberculosis and MDR-TB (Multi drug resistance tuberculosis) suspected patients were enrolled from December, 2013 to April, 2014 in AddisAbaba Health research and Laboratory with mainly young adults of median age 30.5. Afterexcluding 8 samples that were invalid by Xpert MTB/RIF assay 350 samples were analyzedstatistically and The percent agreement between Light Emitted Diode Fluorescent microscopyand Ziehl-Neelsen smear microscopy, Xpert MTB/RIF assay and Light Emitted DiodeFluorescent microscopy, Xpert MTB/RIF assay and Ziehl-Neelsen smear microscopy for MTBdetection showed that k=75%(95%CI,67% to 81%), p<.0005, k=81.8%(95%CI, 81% to 82.6%)p<.0005 and k=72.6%(95%CI,61.6%to82.6%), p<.0005, respectively. The percent agreement of the three tests showed that there were an overall percent agreement of 87.4%, 84.6%, and 90.9%between Light Emitted Diode Fluorescent microscopy and Ziehl-Neelsen microscopy, XpertMTB/RIF assay and Ziehl-Neelsen microscopy, and Light Emitted Diode Fluorescentmicroscopy and Xpert MTB/RIF assay respectively. In the sub group study the sensitivity,specificity, PPV and NPV achieved with direct Ziehl-Neelsen microscopy, Light Emitted DiodeFluorescent microscopy and Xpert MTB/RIF using culture as a gold standard in 167(47%)samples were (76.9%, 96%, 97.8% and 64%), (81.2%, 90%, 95%, 67.2%) and (89.7%, 92%,96.3%, 86.2%) respectively. Conclusion: Xpert MTB/RIF assay has better yield than Light Emitted Diode Fluorescent smearmicroscopy and Ziehl-Neelsen smear microscopy with incremental yield of 12.8% and LightEmitted Diode Fluorescent smear microscopy has better yield than Ziehl-Neelsen smearmicroscopy with incremental yield of 4.8% therefore Xpert MTB/RIF assay is a highly accurate diagnostic tool for MTB detection, which achieves a substantial reduction in diagnostic delayWith overall performance characteristics that are superior to Light Emitted Diode Fluorescentsmear microscopy and Ziehl-Neelsen smear microscopy. Keywords: Light Emitting Diode Fluorescent Microscopy (LED-FM), Ziehl-Neelsen (ZN), Xpert MTB/RIF assay

Home |Privacy policy |End User Agreement |Send Feedback |Library Website

Addis Ababa University © 2023