Skip navigation
 

Please use this identifier to cite or link to this item: http://hdl.handle.net/123456789/14938
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorDr. B.Hundhammeren_US
dc.contributor.advisorDr. Theodros Solomonen_US
dc.contributor.authorAbegaz, Mulat-
dc.date.accessioned2017-05-19T15:05:29Z-
dc.date.available2017-05-19T15:05:29Z-
dc.date.issued1990-06-
dc.identifier.urihttp://hdl.handle.net/123456789/14938-
dc.descriptionA Thesis Presented to the School of Graduate Studies Addis Ababa University in Partial Fulfillment of the Requirements for the Degree of Master of Science in Chemistryen_US
dc.description.abstractUsing the voltammetric senor which is constracted in our laboratory and the membrane stabilized interface between two immiscible electrolyte solution in a flow injection system the transfer of anions (CIO ,NO & 01 )and cations 4 3 (K Na )from the aqueous to the organic phase have been investigated.In order to determine the working potential region of the system the behaviour of the potential-current dependence of the supporting electrolytes were studied. The iR drop resulting fron the diJution effect of the distilled water at the interface has been investigated and it was compensated by increasing the concentration of the supporting electrolyte in the aqueous phase . Dependence of the peak current on the applied potentials and on concentration of various ions (010 , NO , K & Na ) have 4 3 been investigated. The determination of le and Na: was made in the presence of dibenzo-18-crown-6 in the organic phase.The method was applyed to the determination of Na and K in blood serum samples and the values obtained were in good agreement with the values obtained by flame photometric method. The selectivity of the method was also studied and was found to be potential dependent and governed by the partial sensitivity of the individual ion. A method has also been proposed for the determin8tion of a particular ion in the presence of another ion,The detection limit of the detector has been determined to be about 0.25 phi for perchlorate ion . Thus the method is rapid, precise, sensitive for the determination of some anions and cations.en_US
dc.description.sponsorshipAddis Ababa Universityen_US
dc.language.isoen_USen_US
dc.publisherAddis Ababa Universityen_US
dc.titleAnalytical Application of Ion Transfer across the Memembrane Stabilized Interface between Two Immiscible Electrolyte Solutions in a Flow Injection Systemen_US
dc.typeThesisen_US
Appears in Collections:Thesis - Chemistry

Files in This Item:
File Description SizeFormat 
Mulat Abegaz.pdf3.4 MBAdobe PDFView/Open
Show simple item record


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.